Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Building Services Engineering Research and Technology
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Costelloe, B
Right arrow Articles by Finn, D
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Experimental energy performance of open cooling towers used under low and variable approach conditions for indirect evaporative cooling in buildings

B Costelloe, BA MSc CEng MInstE MCIBSE

Department of Building Services Engineering, Dublin Institute of Technology, Ireland

D Finn, BE MEngSc PhD CEng MASHRAE

Department of Mechanical Engineering, University College Dublin, Ireland

The success of chilled ceilings and displacement ventilation systems as a means of sensible cooling in buildings has prompted a review of evaporative cooling technology as an effective means of generating the required cooling water. When such cooling water is generated at low approach conditions (2–5 K), at the higher temperatures required in these systems (14–18°C), very high levels of availability result. In many north western European locations the levels of availability are such that the prospect of supplanting rather than simply supplementing the refrigeration system, for sensible cooling purposes, arises. The viability of the technique, however, largely depends on achieving low approach conditions, at acceptable levels of energy performance. Hence the need to investigate the energy performance of the process. This paper presents the results of recent experimental research into: i) the achievement of low approach conditions in an evaporative cooling test rig; and ii) the energy performance of this test rig when generating cooling water, indirectly, at the temperatures required for chilled ceilings. Energy performance is presented for a range of specifi c conditions and typical annual effi ciencies of cooling water generation are determined. Results are compared with typical energy effi ciencies of conventional, vapour compression based, refrigeration systems. A signifi cant potential for improved annual energy performance, is shown.

Building Services Engineering Research and Technology, Vol. 24, No. 3, 163-177 (2003)
DOI: 10.1191/0143624403bt069oa