Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Click here to register today!

Sign In to gain access to subscriptions and/or personal tools.
Building Services Engineering Research and Technology
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Yu, F.
Right arrow Articles by Chan, K.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Condensing temperature control to enhance the efficiency of air-cooled chillers

FW Yu, BEng

KT Chan, BSc(Eng), MBA, PhD, CEng, FCIBSE

Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong, China

This paper describes an operating strategy of condensing temperature control (CTC), which means regulating the set point of condensing temperature based on the outdoor temperature, to enhance the efficiency of air-cooled chillers used in air-conditioned buildings. A mathematical model of an air-cooled chiller is developed for simulation and is validated by using the operating data of an existing chiller and of an experimental chiller. Compared to head pressure control (HPC) with a fixed set point of condensing temperature, CTC brings a moderate rise in the condensing temperature above the outdoor temperature, and hence enables the compressors to operate at a lower condensing pressure through staging more condenser fans. While more condenser fan power is consumed, compressor power can drop considerablely, reducing the annual chiller power consumption by 18.4%. It is suggested that the condensing temperature can be coupled with the outdoor temperature and the part load ratio of chillers to gauge the achievable part load efficiency.

Building Services Engineering Research and Technology, Vol. 25, No. 4, 279-294 (2004)