Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

CiteULike is a free service for managing and discovering scholarly references - click here to get started.

Sign In to gain access to subscriptions and/or personal tools.
Building Services Engineering Research and Technology
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
0143624409105452v1
30/3/203    most recent
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Wong, L.
Right arrow Articles by Hui, P.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Evaluation on screening strategies for indoor air quality assessments in air-conditioned offices

LT Wong, BEng(Hons) PhD CEng MCIBSE MHKIE RPE

Department of Building Services Engineering,The Hong Kong Polytechnic University, Hong Kong, China

KW Mui, PhD CEng MCIBSE MASHRAE MHKIE RPE

Department of Building Services Engineering,The Hong Kong Polytechnic University, Hong Kong, China, behorace{at}polyu.edu.hk

PS Hui, BEng(Hons) MEng

Department of Building Services Engineering,The Hong Kong Polytechnic University, Hong Kong, China

Unsatisfactory indoor air quality (IAQ) in air-conditioned offices would make the occupants uncomfortable and lead to productivity loss. Strategic IAQ monitoring and assessment conducted with optimised resources for representative pollutants and air sampling are developed. This study proposes a simple screening process; with a readily developed IAQ express assessment protocol (EAP), to improve the accuracy in screening the office environment of unsatisfactory IAQ. This screening process is conducted with an `IAQ index', correlated with an event of unsatisfactory IAQ regarding its `failure' due to other six unmeasured air pollutant levels in the EAP; where the IAQ index is defined as the average fractional dose to certain exposure limits from the assessed top dominant contributors. The screening strategies were examined against the existing IAQ assessment results.

Practical applications: Testing on the screening strategies for EAP in 422 air-conditioned offices in Hong Kong showed that, with a defined screening level of probability of unsatisfactory IAQ, the proposed screening process would improve the overall performance of EAP. It would be a useful source of reference in setting up any practical public IAQ surveillance programmes for policymakers, building owners and professionals to quantify the IAQ problems in offices and make decisions on resources and manpower management for efficient mitigation actions.

This version was published on August 1, 2009

Building Services Engineering Research and Technology, Vol. 30, No. 3, 203-212 (2009)
DOI: 10.1177/0143624409105452


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?