Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Building Services Engineering Research and Technology
This Article
Right arrow Full Text (PDF)
Right arrow A correction has been published
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Baranowski, A.
Right arrow Articles by Ferdyn-Grygierek, J.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Heat demand and air exchange in a multifamily building — simulation with elements of validation

A. Baranowski, MSc PhD

Department of Heating, Ventilation and Dust Removal Technology, Silesian University of Technology, Konarskiego 20, 44-100 Gliwice, Poland, andrzej.baranowski{at}polsl.pl

J. Ferdyn-Grygierek, MSc PhD

Department of Heating, Ventilation and Dust Removal Technology, Silesian University of Technology, Konarskiego 20, 44-100 Gliwice, Poland

The experiment providing data on the energy demand and air exchange in the flat located in the multifamily building is presented in the paper. The measurement was carried out during 3 weeks in winter. The total energy consumption necessary for flat heating was measured continuously. During the same time air change rate in the flat was measured by means of tracer gas concentration decay methods. After measurements were finished the energy demand and ventilating airflows were calculated assuming the same weather data variation as measured during the experiment, using the ESP-r software. Contam program was used for the air infiltration simulation, giving more detailed results about the ventilation airflows within the tested object. Comparison was made between numerical results and measured data over the given cycle and a good correlation of results has been achieved.

Practical applications: Simulation methods can be an alternative to the assessment of energy consumption or heat demand in buildings when the direct measurement is impossible or difficult. A good agreement of simulation and measurement results is reached when the average values of the results are compared for a longer period of time.

Building Services Engineering Research and Technology, Vol. 30, No. 3, 227-240 (2009)
DOI: 10.1177/0143624408338139